1. feed too fast and too much, poor discharge or clogging, control the feed speed and feed amount, and re-adjust the distance between the discharge screw plug and the conical screw at the end of the shaft;
2. improper assembly of screw head and pressure ring, check and reassemble, replace the expansion chamber.